LE3U PLC Compatible with FX3U PLC. With RS485, RTC (real time clock)
- LE3U-14MR / LE3U-14MT PLC industrial control board 8 Input 6 Output 6AD 2DA and RS485 RTC
- LE3U 32MT 6AD2DA 16 input 16 transistor output 6 analog input 2 analog output plc controller RS485 RTC real time clock
LE3U-14MT PLC
Third party Programming Software Description: can be compatible with the programming software Developer7.8 GX or 8.52、8.5 、8.86 Version
Model | FX3U-14MR | FX3U-14MT |
Output type | Relay | Transistor |
Input Voltage | 24V DC | 24V DC |
Output Current | 5A | 1A |
Input Point | 8 | 8 |
Output Point | 6 | 6 |
Analog Input | 6AD | 6AD |
Analog Output | 2DA | 2DA |
High-speed counting | 6 channel | 6 channel |
Pulse output | No | 2 channel |
Floating point | Support | Support |
Step motor | Not Support | Support |
Memory capacity | 8000 steps | 8000 steps |
Download type | Download directly | Download directly |
RS485 | Optional | Optional |
MODBUS | Optional | Optional |
Support text display | YES | YES |
Support HMI Touch Screen | YES | YES |
Software | GX Developer OR GX Works2 | GX Developer OR GX Works2 |
8-point input, 6 transistor outputs
X0-X5 high-speed input, can be accessed by 3 AB encoder, the default 12K
6 analog (3channel 0-10v, 3channel 0-20mA) 2 channel 0-10v analog output
Power-down to maintain, can be set free
DC 24V power supply
3-way AB input
Support for 16-bit encryption,
Supports three kinds of interrupts,
485 communication Support 4 kinds of communication protocols,
Support 1N, 2N, 3U of the instructions,
Power-down to maintain their own set range,
Program 8000 steps,
Download speed 38400,
Floating-point operations,
Scan 3000 steps 1ms
Note: since the international air does not allow the hair contains flammable and explosive goods, so the unity does not contain the battery delivery, thank you for understanding!
The clock module explains when setting the clock, the M8015 should be set and restores the M8015 reset. D8018 is for year, D8017 is month, D8016 is day, D8019 is week, D8015 is hour, D8014 is minute, D8013 is second. The clock data can be read by the clock data TRD to read the clock data to the general register, or to modify the clock with the clock writing instruction TWR, using this instruction without the position M8015
LE3U-32MT PLC
16-point input, 16 transistor outputs
X0-X7 high-speed input, can be accessed by three AB encoder, the default 12K,
6 channel analog (3 channel 0-10v, 3 channel 0-20mA) 2 channel 0-10v analog output
Power-down to maintain, can be set free
DC 24V power supply
3-way AB input
Support for 16-bit encryption,
Supports three kinds of interrupts,
485 communication Support 4 kinds of communication protocols,
Support 1N, 2N, 3U of the instructions,
Power-down to maintain their own set range,
Program 8000 steps,
Download speed 38400,
Floating-point operations,
Scan 3000 steps 1ms
input Power | DC24 |
Number of steps | 8000 steps; 2 communication ports: 1 RS232 (DB9 serial port is communication port for the FX3u protocol 38400,7,E,1; 1 RS485 (485 selection) communication protocol can be set D8120). |
X input element | X0-X27 DC24 input Low level, X0-5 is a high-speed count input port (the Default is 12K) |
Y output element | Y0-Y11 for optimal relay output, relay output current 5A.
4 continuation electric apparatus 1 common end, altogether 3 common ends |
Analog input | 6 analog inputs, 12-bit precision, 3 channel analog input 0-10V, 3 channel analog input 0-20MA; read analog RD3A instruction |
Analog output | 2 analog outputs, 12-bit precision, output voltage: 0-10V. output analog voltage with WR3A instruction |
Intermediate relay | M0-M3071, power-down save range can be set M0-M1023, the default M500-M1023 |
Step point | S0-1023, power-down save range can be set S0-S1023, the default S500-S9999 |
100Ms timer | T0-T199 Accumulated power-down saving T184-T199 |
10Ms timer | T200-T249 Accumulated power-down saving T246-T249 |
1Ms timer | T250-T383, where T250-255 is the cumulative type |
16-bit counter | C0-C199, power-down save C100-C199 |
32-bit counter | C200-C219, save the power-down C220-C234 |
32-bit high-speed counter | C235-255; C235-C240 for the single-phase counter, not multiplier; C241-240 for the single-phase calculator, 2 octave; C2470249 for the dual-phase counter, not multiplier; C250-252 for dual-phase counter, ; C253-C255 for the dual-phase counter, 4 octave |
Register D | D0-D7999, power-down save the range can be set D0-7999 |
Indirect addressing pointer V, Z | V0-7, Z0-7 |
P The subroutine jump number | P0-63 |
I interrupt | X0-5 external interrupt, timer interrupt (1MS unit) counter interrupt |
Special M components | M8000 run-time normally closed, M8002 power pulse, M8011 is 10Ms pulse, M8012 is 100Ms pulse, M8013 is 1s pulse, M8014 is minute pulse |